ESCA 2400/3400/5300

Filter, suction and supply unit (Performance class 2400 – 5300 m³/h)

Key Facts

  • Outlet air suction and filtration, particle removal into collection bins
  • Control of cleaning equipment
  • Power supply for ionisation
  • Compressed air preparation and control
  • Monitoring and signal output
  • The ESCA series (2400/3400/5300) is designed for operating KIST + ESCHERICH surface cleaning devices specifically for applications with high particle volumes. An innovative, cleanable cartridge filter system with an easily removable dust collection bin ensures efficient filtration.

    The airflow cleaned in this way is either discharged into the work environment or routed into an external output air system.

    In addition, the ESCA unit centrally monitors and controls all connected cleaning devices as well as internal components such as the suction fan and the filter cleaning system. External devices – such as ionisers or flow monitors – can also be included in the monitoring system as required. The unit automatically generates warning signals in the event of an error, which are visualised on signal displays and forwarded as external status signals. The ESCA series can also be easily integrated into remote machine controls.

    • Central operating unit with status and error display
    • Display for filter status and collective errors is on the device
    • Monitoring of filters and connected or integrated components and single error message to the remote control
    • Actuation via remote machine control is possible
    • Height-adjustable levelling feet
    • Colour RAL 7035 light grey/ RAL 5003 sapphire blue
    • Additional variants available: ESD

    Suction / filtration

    • Different performance classes, suitable for cleaning devices of various sizes
    • Cleanable cartridge filter system for large particle volumes
    • Easy replacement of the dust collection bin
    • Choice of suction nozzle arrangement for connecting several cleaning stations
  •  ESCA 2400ESCA 3400ESCA 5300
    Volume flow (max.) 2360 m³/h3350 m³/h5200 m³/h
    Number of filter stages111
    Operating voltage3x 400 V, PE, N3x 400 V, PE, N3x 400 V, PE, N
    Frequency50 Hz50 Hz50 Hz
    Rated power4.2 kVA6.8 kVA5.8 kVA
    Rated current (max.)6.0 A9.8 A8.4 A
    Pre-fuse16 A20 A32 A
    Diameter of the suction port
    • 1x DN250
    • 2x DN200
    • 2x DN150
    • 1x DN250
    • 2x DN200
    • 2x DN150
    • 1x DN250
    • 2x DN200
    Diameter of the output air port1x DN150
    or diffused
    1x DN200
    or diffused
    1x DN250
    or diffused
    Pressure difference (max.)2880 Pa3400 Pa3400 Pa
    Compressed Air Qualityfactory, oil-free, dryfactory, oil-free, dryfactory, oil-free, dry
    Operating air pressure inputmax. 8 barmax. 8 barmax. 8 bar
    Ambient temperature (min. – max.)5 – 40 °C5 – 40 °C5 – 40 °C
    Weight368–400 kg393–425 kg420–450 kg
    Degree of protection for control cabinetIP54IP54IP54

    Notes:

    • The maximum volume flow rate and maximum pressure difference are the fan characteristic values in suction mode, free-blowing.
    • The rated power and rated current as well as the weight vary depending on the equipment.
    • The stated weight refers to a variant without added options.
    • Compressed Air Preparation and Control
    • Control of switched cleaning
    • Control and monitoring of cleaning systems with movement
    • Control of ROTORCLEAN cleaning systems
    • Extended monitoring of system parameters (operating pressure, volume flow, rev speed of rotating nozzles)
    • Connection to external systems via Profibus/Profinet
    • Silencer to reduce noise emissions