TAIFUN-CLEAN® CONTROL
Monitoring system for the rotating nozzles of the TAIFUN-CLEAN® cleaning system
![[English] KIST + ESCHERICH TC CONTROL Gruppe](/fileadmin/_processed_/3/d/csm_KIST-ESCHERICH_TAIFUN-CLEAN-Control_10-Grupp_96549acd45.jpg)
Key Facts
Precise control: Permanent rev speed monitoring of the rotating nozzles Flexibility: Up to 24 sensors, can be grouped into 4 monitoring groups Safety: Error detection with external signal and internal protocol Comfort & Protection: illuminated display, independent data storage, protection against incorrect operation
The TAIFUN-CLEAN® CONTROL monitors the rotating nozzles of the TAIFUN-CLEAN® cleaning system and checks that the operations are safe even at mounting positions that are difficult to access or that are not visible. The rev speed of the rotating nozzles is detected with sensors and continuously monitored by the TAIFUN-CLEAN® CONTROL unit. The system puts out an error message and error signals if it falls below or exceeds freely selectable rev speed limits, that can then be addressed remotely.
- Combined detection and evaluation unit
- Connection for up to 24 sensors
- Illuminated alphanumeric display
- Signal contact for external function monitoring
- Internal error log
- Network-independent storage of parameters and errors
- Freely definable sensor inputs, can be grouped into up to
- 4 monitoring groups
- Device is lockable against incorrect operation
- Coupling with ESUC suction and supply units is possible
TCCON10-08 TCCON10-16 TCCON10-24 Supply voltage 24 V DC 24 V DC 24 V DC Current consumption max. 250 mA 250 mA 250 mA Ingress protection IP54 IP54 IP54 Connectible sensor type PNP-NO, 4-pole M8 plug connector, max. 10 m length of cable per sensor PNP-NO, 4-pole M8 plug connector, max. 10 m length of cable per sensor PNP-NO, 4-pole M8 plug connector, max. 10 m length of cable per sensor Max. number of connecting sensors 8 16 24 Working temperature (min. - max.) 5 – 60 °C 5 – 60 °C 5 – 60 °C Weight 1500 g 1600 g 1700 g - Datasheet